Inadvertent intravesicular placement of a vaginal contraceptive ring: a case report and review of literature

Authors

  • Kevin Scott Baker
  • Matthew Barish

DOI:

https://doi.org/10.3941/jrcr.v8i12.2304

Keywords:

Intravesicular foreign body, foreign body, contraceptive ring, NuvaRing, contraception radiology, CT imaging

Abstract

The NuvaRing® is a deformable, ring-shaped hormonal contraceptive device which is typically vaginally self-inserted by the patient.  While there are several potential side effects of usage, essentially all of them result from hormone delivery.  Complications from incorrect placement are rare.  We present the case of a 31 year old female who presented to our emergency department after being unable to retrieve a NuvaRing® for its scheduled removal.  CT scan showed a hypodense intravesicular NuvaRing® which the patient had inadvertently placed transurethrally 3 weeks prior.  Cystoscopy was performed and retrieval using a 3-pronged grasper was eventually successful after several failed attempts with an alligator grasper.  Our purpose in presenting this case is to introduce the reader to a rare complication of incorrect NuvaRing® placement, explain how this complication may occur as a result of NuvaRing® construction/functionality, describe how alternative cystoscopic instruments may aid in cystoscopic retrieval, and review the 3 other case reports of intravesicular NuvaRing® placement to discuss the utility of various imaging modalities when clinical suspicion of the complication is high.

Published

2014-12-14

Issue

Section

Genitourinary Radiology